Sunday, May 13, 2007

SCR Tester


This handy tester will provide a visual "on" or "off" switching and latching indication. When finished, you can test all those posible 'duds' in your junkbox and dump some of those in the garbage. If the scr is latching and can hold the latch it is most likely okay.

Look at the circuit diagram, it shows a 3-amp, 50-volt SCR (under test) and a test circuit. Points "Gate" and "Kathode" are temporary connections, so that they can easily be opened. I used toggle switches for each, but use whatever you feel comfortable with, a simple jumper wire would do the trick. I use this gadget in my shop and so have it mounted in a small case. This circuit can even be bread-boarded for your purpose.

When "Kathode" is closed, the lamp doesn't light. When "Gate" is also closed, the lamp lights to its full intensity. The lamp remains lit even if "Gate" is opened again. But when "Kathode" is opened, even momentarily, the lamp does not close again when "Kathode" is closed. That illustrates the "ON" and "OFF" operation of the SCR.
I tested the following SCR types: C106D1 (400V/4A)     
T106Y1 (30V/4A)
C106F (50V/4A)
C106F1 (50V/4A)
C106B (200V/4A)
CSM2B2 (100V/4A)
T106D1 (400V/4A)
NTE5402 (100V/0.8A)
TIC106M (600V/8A)
NTE5457 (400V/4A)
TIC126M (600V/25A)
CR6AM-8 (400V/10A)
MCR106-3 (100V/4A)
NTE5455 (200V/4A)


In all cases the tester was accurate in telling 'good'
from the 'bad'.






No comments: